Aqua-Hot Furnace: “Fault Code 9”
warning RV furnace fault codes
What it means
Re-ignition failure. The burner lit and established a flame, the flame then went out during operation, and the burner failed to re-light on its re-ignition sequence.
Most likely causes
- Dirty or fouled flame sensor lens so the controller cannot confirm the re-lit flame most likely
- Obstructed or contaminated fuel nozzle interrupting fuel delivery common
- Too much combustion air for the burner less common
- Poor chassis ground connection less common
Safe checks you can do yourself
- Inspect and gently clean the flame sensor lens so it can detect flame
- Check the fuel nozzle for obstructions or contaminants
- Verify the combustion-air setting is correct (not set too high)
- Confirm the chassis ground connection is clean and secure
How to reset / clear Fault Code 9
- Clean the flame sensor lens and clear any fuel/air issue first
- Turn the diesel-burner switch OFF for about 30 seconds
- Turn the switch back ON to clear the fault and restart
When to call a technician
If cleaning the flame sensor and checking the nozzle, combustion air and ground do not resolve repeated flame-outs, have the burner serviced or call Aqua-Hot Technical Support at 1-800-685-4298.
Applies to
Aqua-Hot 375-D02 · AHE-375-D02
FAQ
What does Aqua-Hot Furnace code "Fault Code 9" mean?
Re-ignition failure. The burner lit and established a flame, the flame then went out during operation, and the burner failed to re-light on its re-ignition sequence.
How do I reset Aqua-Hot Furnace Fault Code 9?
Clean the flame sensor lens and clear any fuel/air issue first Turn the diesel-burner switch OFF for about 30 seconds Turn the switch back ON to clear the fault and restart
What is the most common cause of Fault Code 9 on a Aqua-Hot Furnace?
The most likely cause is dirty or fouled flame sensor lens so the controller cannot confirm the re-lit flame.
Related · Aqua-Hot furnace
The diesel-burner indicator light is not lit even though the… Fault Code 1
Low supply voltage detected by the diesel-burner controller.… Fault Code 8
The burner failed to ignite on its initial start attempt, or…
Sources
- Aqua-Hot 375-D02 Hydronic Heating System Service Manual (Rev. E) — Section 9, Fault Code 9, p.95 (Aqua-Hot Heating Systems Inc.)
Note: Specific to the 375-D02 controller; blink assignments vary across Aqua-Hot models.
● Last verified 2026-06-29 · compiled from manufacturer documentation. Codes can vary by model year — always cross-check your unit’s manual.