warning RV air conditioner error codes
What it means
The CCC2 thermostat reads an open circuit on the optional humidity sensor (only fitted on select models). Cooling and dehumidify modes are disabled for the affected zone, but heat pump, furnace, electric heat strip, and fan keep running.
Most likely causes
- Open or disconnected humidity sensor wiring on a model equipped with that sensor most likely
- Failed humidity sensor element common
- Corroded or loose sensor connector at the power module board less common
Safe checks you can do yourself
- Confirm your unit actually has the optional humidity sensor — many CCC2 installs do not, and a stray E6 can indicate a wiring issue rather than a real sensor.
- Visually inspect the humidity sensor connector at the air conditioner power module for looseness or corrosion (power off first).
- Note whether cooling still works in other zones, which helps localize the fault to one unit.
How to reset / clear E6
- Turn the system off at the thermostat.
- Remove 120 VAC shore/generator power and 12V DC power for at least 5 minutes to clear the controller.
- Restore power and observe whether E6 returns.
When to call a technician
Call an RV HVAC technician if the humidity sensor and its wiring check out but E6 persists, since accessing the rooftop power module and sensor harness involves line voltage.
Applies to
Dometic Brisk II · Dometic Penguin II · Select CCC2-equipped models with optional humidity sensor
FAQ
What does Dometic Air Conditioner code "E6" mean?
The CCC2 thermostat reads an open circuit on the optional humidity sensor (only fitted on select models). Cooling and dehumidify modes are disabled for the affected zone, but heat pump, furnace, electric heat strip, and fan keep running.
How do I reset Dometic Air Conditioner E6?
Turn the system off at the thermostat. Remove 120 VAC shore/generator power and 12V DC power for at least 5 minutes to clear the controller. Restore power and observe whether E6 returns.
What is the most common cause of E6 on a Dometic Air Conditioner?
The most likely cause is open or disconnected humidity sensor wiring on a model equipped with that sensor.
Related · Dometic air conditioner
Electronics and drive faults on the FreshJet inverter board.… E1
The thermostat has lost its communication link with the air … E2
The indoor (return-air) temperature sensor is reading open-c… E3
The indoor (return-air) temperature sensor is reading as sho… E4
The outdoor temperature sensor (fitted on select heat-pump m… E5
The freeze sensor is reading open-circuit or out of range (d…
Sources
- Comfort Control Center 2 Thermostat User's Guide — Form No. 3314150.016, LCD Error Code section, E6 (Dometic LLC (hosted by My RV Works))
- Dometic Comfort Control Center 2 Users Guide — Error code table, E6 (thermostat.guide)
Note: Only applies to units actually equipped with the optional humidity sensor; on units without it E6 should not normally appear.
● Last verified 2026-06-29 · compiled from manufacturer documentation. Codes can vary by model year — always cross-check your unit’s manual.