P4 / P5 / P6 / P7

Dometic Air Conditioner: “P4 / P5 / P6 / P7”

warning RV air conditioner error codes

Safety Do not attempt to add refrigerant or open the sealed circuit — this requires a certified technician and is regulated. Disconnect shore power and the AC breaker before any rooftop access.

What it means

Refrigerant-circuit temperature protections. P4 = discharge tube (compressor outlet) overheat. P5 = evaporator coil protection in cooling. P6 = condenser coil protection in cooling. P7 = evaporator coil protection in heating. Each trips the compressor to prevent damage from abnormal coil/line temperatures.

Most likely causes

  1. Restricted airflow over the evaporator (dirty filter/coil) or condenser (blocked rooftop vents) most likely
  2. Operating outside the unit's rated ambient temperature range common
  3. Low refrigerant charge or a refrigerant-circuit fault less common

Safe checks you can do yourself

How to reset / clear P4 / P5 / P6 / P7

  1. Turn the unit off, clear any airflow restriction
  2. Disconnect power for about 2 minutes, then restore and restart

When to call a technician

If these codes recur after the filter and both coils/airflow paths are clean and ambient is in range, contact an authorized Dometic service agent — a refrigerant or sensor fault is likely.

Applies to

Dometic FreshJet Series 4 (FJX) · Dometic FreshJet Series 7 (FJX) · FreshJet inverter rooftop units

FAQ

What does Dometic Air Conditioner code "P4 / P5 / P6 / P7" mean?

Refrigerant-circuit temperature protections. P4 = discharge tube (compressor outlet) overheat. P5 = evaporator coil protection in cooling. P6 = condenser coil protection in cooling. P7 = evaporator coil protection in heating. Each trips the compressor to prevent damage from abnormal coil/line temperatures.

How do I reset Dometic Air Conditioner P4 / P5 / P6 / P7?

Turn the unit off, clear any airflow restriction Disconnect power for about 2 minutes, then restore and restart

What is the most common cause of P4 / P5 / P6 / P7 on a Dometic Air Conditioner?

The most likely cause is restricted airflow over the evaporator (dirty filter/coil) or condenser (blocked rooftop vents).

Related · Dometic air conditioner

Note: FreshJet FJX inverter models only. Grouped as coil/discharge temperature protections; they are four separate codes. P8 is not listed in the manual table.