Err 33

Victron Energy Solar Charge Controller: “Err 33”

danger RV solar charge controller error codes

Safety PV strings that overvoltage the controller carry dangerous, potentially lethal DC. Cold mornings raise voltage further. Always isolate/cover the array before changing string wiring, and never assume PV is dead in daylight.

What it means

PV over-voltage. The solar input voltage exceeded the controller's maximum rated PV voltage, so the controller shut down the PV input to protect itself.

Most likely causes

  1. Too many panels wired in series for the controller's max PV voltage most likely
  2. Cold weather raising panel open-circuit voltage (Voc) above the limit common

Safe checks you can do yourself

How to reset / clear Err 33

  1. No manual reset needed: the controller auto-resets once the PV voltage drops back below the safe limit

When to call a technician

PV voltage is within rating but Err 33 persists, suggesting a measurement or internal fault.

Applies to

SmartSolar MPPT (all) · BlueSolar MPPT (all)

FAQ

What does Victron Energy Solar Charge Controller code "Err 33" mean?

PV over-voltage. The solar input voltage exceeded the controller's maximum rated PV voltage, so the controller shut down the PV input to protect itself.

How do I reset Victron Energy Solar Charge Controller Err 33?

No manual reset needed: the controller auto-resets once the PV voltage drops back below the safe limit

What is the most common cause of Err 33 on a Victron Energy Solar Charge Controller?

The most likely cause is too many panels wired in series for the controller's max pv voltage.

Related · Victron Energy solar charge controller

Note: Official title and auto-reset behavior confirmed.

Last verified 2026-06-29 · compiled from manufacturer documentation. Codes can vary by model year — always cross-check your unit’s manual.