Alde Furnace: “Gas failure”
warning RV furnace fault codes
What it means
The boiler tried to ignite the LPG burner but did not establish a flame, or it ran out of gas. The control panel reports that gas heating could not start.
Most likely causes
- LPG cylinder empty or shut off most likely
- Gas isolation valve closed, or regulator/valve frozen in cold weather common
- Wrong gas type or a regulator fault less common
- Ignition or gas valve fault in the boiler less common
Safe checks you can do yourself
- Check that the LPG cylinder is not empty and the bottle valve is open
- Try a different, known-full propane cylinder
- Confirm all gas isolation valves are open and the regulator is not frozen or iced over
- Verify the gas supply is propane as required
How to reset / clear Gas failure
- Restore the gas supply (open valves, swap to a full propane bottle)
- Reset from the panel: disconnect the panel from the boiler, remove 230V, and disconnect 12V from the boiler
- Reconnect power and restart the boiler on gas
When to call a technician
If the gas supply is confirmed good and valves are open but the boiler still will not ignite on gas, or if you suspect a gas leak, regulator fault or ignition fault, contact an Alde dealer or qualified gas technician.
Applies to
Alde Compact 3020 HE
FAQ
What does Alde Furnace code "Gas failure" mean?
The boiler tried to ignite the LPG burner but did not establish a flame, or it ran out of gas. The control panel reports that gas heating could not start.
How do I reset Alde Furnace Gas failure?
Restore the gas supply (open valves, swap to a full propane bottle) Reset from the panel: disconnect the panel from the boiler, remove 230V, and disconnect 12V from the boiler Reconnect power and restart the boiler on gas
What is the most common cause of Gas failure on a Alde Furnace?
The most likely cause is lpg cylinder empty or shut off.
Related · Alde furnace
The 12V supply to the boiler has dropped below about 10.5V, … Overheat (red fail)
The overheat protection on the red cable has tripped. The bo… Overheat PCB
The boiler's circuit board (PCB) failsafe over-temperature p…