E3

Coleman-Mach Air Conditioner: “E3”

warning RV air conditioner error codes

Safety De-energize the A/C breaker and 120V supply before opening the ceiling assembly; line voltage is present in the rooftop unit. Leave sensor or board replacement to a qualified RV HVAC technician.

What it means

The indoor (room) temperature sensor is reading as shorted. As with E2, the thermostat can't trust the room temperature, so heating and cooling are locked out while the fan can still run.

Most likely causes

  1. Shorted indoor/room temperature sensor most likely
  2. Sensor wiring shorted (pinched/chafed conductors touching) common
  3. Moisture or corrosion bridging the sensor terminals less common
  4. Failed thermostat input circuit less common

Safe checks you can do yourself

How to reset / clear E3

  1. Turn OFF the A/C breaker, wait ~60 seconds, then restore power.
  2. If E3 clears and stays clear, it was transient.
  3. If it returns, the indoor sensor or wiring likely needs replacement.

When to call a technician

E3 persists after checking wiring and a power cycle, or the room sensor must be replaced.

Applies to

Coleman-Mach single-zone LCD wall thermostat · Coleman-Mach rooftop A/C systems using a remote/indoor room temperature sensor

FAQ

What does Coleman-Mach Air Conditioner code "E3" mean?

The indoor (room) temperature sensor is reading as shorted. As with E2, the thermostat can't trust the room temperature, so heating and cooling are locked out while the fan can still run.

How do I reset Coleman-Mach Air Conditioner E3?

Turn OFF the A/C breaker, wait ~60 seconds, then restore power. If E3 clears and stays clear, it was transient. If it returns, the indoor sensor or wiring likely needs replacement.

What is the most common cause of E3 on a Coleman-Mach Air Conditioner?

The most likely cause is shorted indoor/room temperature sensor.

Related · Coleman-Mach air conditioner

Note: Original-English compilation from RV HVAC references mirroring the Coleman-Mach single-zone LCD code list; manufacturer PDF table not directly openable. Some generic (non-RV) Coleman mini-split charts assign E3 to a fan-speed fault, so this record is scoped specifically to the Coleman-Mach RV single-zone LCD thermostat. LCD-display models only.

Last verified 2026-06-29 · compiled from manufacturer documentation. Codes can vary by model year — always cross-check your unit’s manual.