Er

Coleman-Mach Air Conditioner: “Er”

warning RV air conditioner error codes

Safety Switch off the A/C breaker and 120V power before opening any ceiling control box; rooftop zone boards are near line-voltage wiring. The system will not operate below about 9.75V DC, so verify house battery health before assuming a fault. Leave board/sensor replacement to a qualified RV HVAC technician.

What it means

On the Coleman-Mach multi-zone LCD thermostat, 'Er' appears in the temperature area of the display when the measured ambient temperature is outside the thermostat's usable range, or when there is a problem with one of the remote temperature sensors. It signals the thermostat cannot show or act on a valid temperature for that situation/zone.

Most likely causes

  1. Remote (zone) temperature sensor disrupted, disconnected, or faulty most likely
  2. Loose or corroded sensor wiring at the zone control box common
  3. Actual room temperature outside the thermostat's display/operating limits less common
  4. Failed sensor or board input less common

Safe checks you can do yourself

How to reset / clear Er

  1. Turn OFF the A/C breaker, wait ~60 seconds, then restore power.
  2. Let the thermostat re-detect connected zones on startup.
  3. If 'Er' returns for a specific zone, inspect/replace that zone's remote sensor (qualified service).

When to call a technician

'Er' stays for a zone after checking that zone's sensor wiring and a power cycle, or a remote sensor/board must be replaced.

Applies to

Coleman-Mach multi-zone LCD wall thermostat (e.g. 9330-33 / 9430 multi-zone control packages) · Coleman-Mach zone-controlled rooftop A/C systems with remote room sensors

FAQ

What does Coleman-Mach Air Conditioner code "Er" mean?

On the Coleman-Mach multi-zone LCD thermostat, 'Er' appears in the temperature area of the display when the measured ambient temperature is outside the thermostat's usable range, or when there is a problem with one of the remote temperature sensors. It signals the thermostat cannot show or act on a valid temperature for that situation/zone.

How do I reset Coleman-Mach Air Conditioner Er?

Turn OFF the A/C breaker, wait ~60 seconds, then restore power. Let the thermostat re-detect connected zones on startup. If 'Er' returns for a specific zone, inspect/replace that zone's remote sensor (qualified service).

What is the most common cause of Er on a Coleman-Mach Air Conditioner?

The most likely cause is remote (zone) temperature sensor disrupted, disconnected, or faulty.

Related · Coleman-Mach air conditioner

Note: Confirmed from the OEM-hosted Airxcel/RVP multi-zone operation guide PDF (text extracted directly). The multi-zone LCD thermostat uses 'Er' rather than the E1-E5 numbering used by the single-zone LCD thermostat; wording is an original-English summary, not copied manual prose.

Last verified 2026-06-29 · compiled from manufacturer documentation. Codes can vary by model year — always cross-check your unit’s manual.