Orange solid (overload/short)

Go Power Inverter / Charger: “Orange solid (overload/short)”

warning RV inverter fault codes

Safety A short circuit can cause heat and arcing. Disconnect AC loads before inspecting, and treat the 120V AC output as live and potentially lethal. Have AC wiring repaired by a qualified person.

What it means

Over Load Protection or Short Circuit Protection. While inverting or in AC pass-through, the unit detected an AC overload or output short circuit and shut down. The status LED is solid orange; the alarm sounds five beeps. (Orange slow blink indicates Over Temperature, orange fast blink indicates Under Temperature.)

Most likely causes

  1. AC load exceeds the inverter's rated output most likely
  2. High surge load from a motor or compressor at startup common
  3. Short circuit in AC output wiring or a faulty appliance less common

Safe checks you can do yourself

How to reset / clear Orange solid (overload/short)

  1. Reduce or remove the load (or clear the short)
  2. Turn the inverter back on using the on/off switch on the unit or the remote control

When to call a technician

If the overload/short fault occurs with little or no load, or you suspect a short inside the AC output wiring, stop using the unit and contact a qualified technician.

Applies to

IC-2000-12 · IC-3000-12 · IC Series Inverter/Charger

FAQ

What does Go Power Inverter / Charger code "Orange solid (overload/short)" mean?

Over Load Protection or Short Circuit Protection. While inverting or in AC pass-through, the unit detected an AC overload or output short circuit and shut down. The status LED is solid orange; the alarm sounds five beeps. (Orange slow blink indicates Over Temperature, orange fast blink indicates Under Temperature.)

How do I reset Go Power Inverter / Charger Orange solid (overload/short)?

Reduce or remove the load (or clear the short) Turn the inverter back on using the on/off switch on the unit or the remote control

What is the most common cause of Orange solid (overload/short) on a Go Power Inverter / Charger?

The most likely cause is ac load exceeds the inverter's rated output.

Related · Go Power inverter / charger

Note: Overload/short requires a manual restart via the on/off switch; over-temperature (orange slow blink) instead auto-restarts after cooling.

Last verified 2026-06-29 · compiled from manufacturer documentation. Codes can vary by model year — always cross-check your unit’s manual.