Red fast blink (UVP)

Go Power Inverter / Charger: “Red fast blink (UVP)”

warning RV inverter fault codes

Safety Batteries can deliver dangerous short-circuit currents and lead-acid types vent explosive hydrogen. Wear eye protection, avoid sparks near batteries, and do not short DC terminals when checking connections.

What it means

Under Voltage Protection / Low Battery. The DC input voltage is below specification (battery reached the Low Battery Cut Out, default 10.5 VDC), so the inverter shuts down to protect the battery. The status LED fast-blinks red; the alarm sounds four beeps.

Most likely causes

  1. Battery bank discharged to the low-voltage cutout most likely
  2. Undersized DC cabling or loose/corroded connections causing voltage drop common
  3. Aged or failing battery common
  4. Blown DC fuse or open circuit breaker in the DC path less common

Safe checks you can do yourself

How to reset / clear Red fast blink (UVP)

  1. Supply AC shore power and let the battery recover above the Low Battery Cut In (12.5 VDC); the unit restarts automatically
  2. Alternatively turn the unit off and on at the on/off switch or remote after the battery recovers

When to call a technician

If the battery will not hold charge or UVP recurs with a charged, properly cabled battery, have the battery and DC system serviced.

Applies to

IC-2000-12 · IC-3000-12 · IC Series Inverter/Charger

FAQ

What does Go Power Inverter / Charger code "Red fast blink (UVP)" mean?

Under Voltage Protection / Low Battery. The DC input voltage is below specification (battery reached the Low Battery Cut Out, default 10.5 VDC), so the inverter shuts down to protect the battery. The status LED fast-blinks red; the alarm sounds four beeps.

How do I reset Go Power Inverter / Charger Red fast blink (UVP)?

Supply AC shore power and let the battery recover above the Low Battery Cut In (12.5 VDC); the unit restarts automatically Alternatively turn the unit off and on at the on/off switch or remote after the battery recovers

What is the most common cause of Red fast blink (UVP) on a Go Power Inverter / Charger?

The most likely cause is battery bank discharged to the low-voltage cutout.

Related · Go Power inverter / charger

Note: Default LBCO is 10.5 VDC but is adjustable with the GP-ICR-50 remote.