Onan Generator: “Fault 15”
warning RV generator fault codes
What it means
Underfrequency fault. The engine governor could not keep the engine spinning fast enough to maintain rated output frequency (Hz), so the controller shut the unit down.
Most likely causes
- Excessive electrical load overworking the engine/governor (A/C plus chargers) most likely
- On high-pressure LPG models: oil migrated from the supply system into the genset LPG plumbing, starving fuel common
- Air cleaner restriction or a fuel-delivery problem limiting power less common
Safe checks you can do yourself
- Reduce the number of connected appliances, especially air conditioners and active battery chargers, then restart.
- On high-pressure LPG models only: with the system depressurized, drain accumulated oil from the genset LPG drain valve per the manual, then be sure to re-close the drain valve.
- Check that the air cleaner is not clogged.
How to reset / clear Fault 15
- Shed load and/or clear the LPG oil, then restart from the control switch.
- Confirm the unit holds frequency under your normal load.
When to call a technician
If underfrequency continues after reducing load and (on LPG units) draining oil — the governor or fuel system likely needs a dealer.
Applies to
Marquis Gold · QG 4000 · QG 5500 · KY series · HGJAA · HGJAB · HGJAC · HGJAD · HGJAE · HGJAF
FAQ
What does Onan Generator code "Fault 15" mean?
Underfrequency fault. The engine governor could not keep the engine spinning fast enough to maintain rated output frequency (Hz), so the controller shut the unit down.
How do I reset Onan Generator Fault 15?
Shed load and/or clear the LPG oil, then restart from the control switch. Confirm the unit holds frequency under your normal load.
What is the most common cause of Fault 15 on a Onan Generator?
The most likely cause is excessive electrical load overworking the engine/governor (a/c plus chargers).
Related · Onan generator
Low oil pressure fault (a first-level fault shown as two bli… Fault 3
First-level 'service check' fault. Three blinks tell you the… Fault 12
Overvoltage fault. The controller could not keep the output … Fault 13
Undervoltage fault. The controller could not hold the genera… Fault 14
Overfrequency fault. The engine governor could not hold the … Fault 19
Governor actuator fault. The controller detected an open or …
Sources
- Onan Troubleshooting Codes (Service Manual Table 5) — Underfrequency Fault — Code No. 15 (Cummins Onan (hosted by Heartland Owners))
Note: The LPG oil-drain step applies only to high-pressure LPG models; gasoline and low-pressure LPG units skip it.
● Last verified 2026-06-29 · compiled from manufacturer documentation. Codes can vary by model year — always cross-check your unit’s manual.