Fault 22

Onan Generator: “Fault 22”

warning RV generator fault codes

Safety This is a fuel-burning engine. Never run it in an enclosed space or occupy the vehicle while it runs without a working carbon monoxide detector, and let hot parts cool before touching anything.

What it means

Governor actuator overload. The controller had to hold the governor actuator at full duty cycle — maximum pulse-width-modulated signal — for 60 consecutive seconds to keep engine speed up, and shut down. In other words the engine was being asked for more than it could deliver, for a full minute.

Most likely causes

  1. Too much load, particularly motor starting loads such as air conditioners most likely
  2. Engine down on power — restricted air filter, fuel restriction or a worn engine common
  3. High altitude or high ambient temperature reducing available output less common

Safe checks you can do yourself

How to reset / clear Fault 22

  1. Reduce the load and restart.
  2. To re-display a logged code, press Stop three times within five seconds — the blinking times out after five minutes (fifteen on the HGJAA series). The controller keeps replaying the last fault even after the cause is gone; only a successful run clears it.

When to call a technician

It trips at loads the genset used to carry comfortably — that points at engine performance rather than at your appliances.

Accuracy notes

Do not confuse this with code 19. Code 19 is an electrical fault in the actuator or its harness and is a dealer job; code 22 is a working actuator being asked for too much, and is usually fixed by the person operating the generator.

Applies to

Onan Quiet Diesel HDKCA / HDKCB · Onan gensets with an electronic governor actuator

FAQ

What does Onan Generator code "Fault 22" mean?

Governor actuator overload. The controller had to hold the governor actuator at full duty cycle — maximum pulse-width-modulated signal — for 60 consecutive seconds to keep engine speed up, and shut down. In other words the engine was being asked for more than it could deliver, for a full minute.

How do I reset Onan Generator Fault 22?

Reduce the load and restart. To re-display a logged code, press Stop three times within five seconds — the blinking times out after five minutes (fifteen on the HGJAA series). The controller keeps replaying the last fault even after the cause is gone; only a successful run clears it.

What is the most common cause of Fault 22 on a Onan Generator?

The most likely cause is too much load, particularly motor starting loads such as air conditioners.

Related · Onan generator

Checked against 1 manufacturer document · Last verified 2026-08-07 · compiled from manufacturer documentation. Codes can vary by model year — always cross-check your unit’s manual. How we verify