Fault 19

Onan Generator: “Fault 19”

warning RV generator fault codes

Safety Do not attempt to adjust or repair the governor yourself; improper governor work can cause overspeed and serious damage or injury. Disconnect the negative battery cable before any inspection.

What it means

Governor actuator fault. The controller detected an open or shorted circuit in the electronic governor actuator that regulates engine speed.

Most likely causes

  1. Open or short in the governor actuator or its wiring most likely
  2. Failed governor actuator common

Safe checks you can do yourself

How to reset / clear Fault 19

  1. This is a dealer-service fault; no owner reset clears the underlying cause.

When to call a technician

Whenever Code 19 appears — the manufacturer directs this to an authorized Onan dealer.

Accuracy notes

Documented on the liquid-cooled Quiet Diesel sets, which measure the actuator circuit at startup; the manual gives 2.8 to 2.9 ohms across the actuator leads as the expected resistance. Do not confuse it with code 22, which is a healthy actuator held at full duty cycle by too much load — that one is fixed by the operator, this one by a dealer.

Applies to

Marquis Gold · QG 4000 · QG 5500 · KY series · HGJAA · HGJAB · HGJAC · HGJAD · HGJAE · HGJAF

FAQ

What does Onan Generator code "Fault 19" mean?

Governor actuator fault. The controller detected an open or shorted circuit in the electronic governor actuator that regulates engine speed.

How do I reset Onan Generator Fault 19?

This is a dealer-service fault; no owner reset clears the underlying cause.

What is the most common cause of Fault 19 on a Onan Generator?

The most likely cause is open or short in the governor actuator or its wiring.

Related · Onan generator

Checked against 2 manufacturer documents · Last verified 2026-08-07 · compiled from manufacturer documentation. Codes can vary by model year — always cross-check your unit’s manual. How we verify