Fault 31

Onan Generator: “Fault 31”

danger RV generator fault codes

Safety An over-speeding engine can fail violently. Keep clear and do not run it. This is a fuel-burning engine - if you smell gas or propane, stop and ventilate; never run in an enclosed space due to carbon monoxide.

What it means

Overspeed fault. The engine speed exceeded 3400 rpm, so the controller shut the generator down to protect it. Read as three blinks, a pause, then one blink.

Most likely causes

  1. Governor or governor-actuator malfunction allowing engine to run away common
  2. Controller / speed-sensing fault common
  3. Throttle/linkage or fuel system fault driving speed too high less common

Safe checks you can do yourself

How to reset / clear Fault 31

  1. The official corrective action is to see an authorized Onan dealer - overspeed is not a homeowner adjustment.
  2. To re-read the logged code, press Stop three times within 5 seconds (the code stops blinking after about 5 minutes).

When to call a technician

Always for overspeed - the manufacturer directs you to an authorized Onan/Cummins dealer rather than DIY repair.

Accuracy notes

Overspeed is the true meaning of 31, and it is frequently confused with 36. Worth knowing where it applies: code 31 appears in Onan troubleshooting tables for other series, but it is in neither the KY (Spec J–N) operator manual nor the HDKCA/HDKCB Quiet Diesel manual. Check the table for your own model and spec letter before acting on it.

Applies to

Onan RV QG / KY series RV gensets · Onan blink-code-controller RV gensets (HGJAA/HGJAB-class)

FAQ

What does Onan Generator code "Fault 31" mean?

Overspeed fault. The engine speed exceeded 3400 rpm, so the controller shut the generator down to protect it. Read as three blinks, a pause, then one blink.

How do I reset Onan Generator Fault 31?

The official corrective action is to see an authorized Onan dealer - overspeed is not a homeowner adjustment. To re-read the logged code, press Stop three times within 5 seconds (the code stops blinking after about 5 minutes).

What is the most common cause of Fault 31 on a Onan Generator?

The most likely cause is governor or governor-actuator malfunction allowing engine to run away.