Dometic Refrigerator: “E50”
danger RV refrigerator error codes
What it means
Gas ignition lockout: the burner failed to light after three automatic ignition attempts, so the controller locks out gas operation.
Most likely causes
- Empty or closed LP cylinder / no gas reaching the burner most likely
- Air in the gas line after running the tank empty or after service common
- Clogged burner jet/orifice, weak igniter, or fouled electrode common
Safe checks you can do yourself
- Check that the propane cylinder has gas and the valve is open; confirm another LP appliance lights.
- Purge air from the line by running a stovetop burner briefly (if equipped and safe), then retry.
- Inspect the burner area for spider webs or debris (only with gas off and once cool).
How to reset / clear E50
- E50 is an ERROR-type fault: after restoring gas, press and hold the control/encoder button about 2 seconds until a beep to reset and allow re-ignition.
- If it relocks after three more attempts, stop and investigate the gas path.
When to call a technician
If the cylinder has gas, the line is purged, and E50 still locks out, have the burner, orifice, and igniter serviced by a qualified RV gas technician.
Applies to
RMD10.5 · RMD10.5S · RMD10.5T · RMD10.5X · RMD10.5XS · RMD10.5XT
FAQ
What does Dometic Refrigerator code "E50" mean?
Gas ignition lockout: the burner failed to light after three automatic ignition attempts, so the controller locks out gas operation.
How do I reset Dometic Refrigerator E50?
E50 is an ERROR-type fault: after restoring gas, press and hold the control/encoder button about 2 seconds until a beep to reset and allow re-ignition. If it relocks after three more attempts, stop and investigate the gas path.
What is the most common cause of E50 on a Dometic Refrigerator?
The most likely cause is empty or closed lp cylinder / no gas reaching the burner.
Related · Dometic refrigerator
Voltage fault. The DC supply voltage reaching the fridge is … 2 red LED flashes
Excessive fan current. The condenser/cooling fan is drawing … 3 red LED flashes
The motor (compressor) does not start. The electronics tried… 4 red LED flashes
Compressor speed too low. The cooling system is so heavily l… 05 / W05
AC (230 V mains) power problem: the fridge is set to run on … 5 red LED flashes
Overheating of the electronics unit. The compressor's contro…
Sources
- Dometic 10 Series Error code reference (gas lock after 3 ignition attempts) — 10 Series OPM, Error type fault messages, E50 (gas lock after 3 ignition attempts — empty cylinder, replace/reset) (Dometic / ManualsLib)
- Dometic RMD10.5 Operating manual (Troubleshooting — gas lock) — Section 7.1 — Gas lock after 3 ignition attempts; gas cylinder empty, replace, reset (Dometic)
Note: Related higher gas-fault codes exist on the same board — E51 (gas lock, internal power-module error), E52 (ground contact/short on the gas valve), and E53 (ground contact/short on the ignition electrode) — all of which require service if they recur.
● Last verified 2026-06-29 · compiled from manufacturer documentation. Codes can vary by model year — always cross-check your unit’s manual.