Oven lights then goes out

Furrion Stove / Range: “Oven lights then goes out”

warning RV stove & oven problems

Safety The flame-supervision/thermocouple system is a primary gas safety device. Do not bypass, wedge, or defeat it. If the oven keeps shutting off, that may be the safety doing its job, not a nuisance to disable. A faulty safety device that leaves the valve open lets raw propane escape, which is an explosion and CO hazard. Always run a CO/LP detector.

What it means

The oven ignites but the flame extinguishes once the knob is released or shortly after. This is the classic flame-supervision-device (thermocouple) fault: the thermocouple must be heated by the pilot/burner flame to generate the small voltage that holds the gas safety valve open. If it does not get hot enough, the safety valve closes and shuts off gas, which is the device working as intended on a marginal flame.

Most likely causes

  1. Thermocouple tip not fully in the flame, bent, or misaligned so it never gets hot enough most likely
  2. Loose thermocouple connection nut at the gas valve common
  3. Knob released too soon before the flame and thermocouple stabilized (hold ~5+ seconds) common
  4. Dirty pilot/burner producing a weak, lazy flame common
  5. Worn-out thermocouple that no longer generates sufficient voltage less common
  6. Inadequate combustion air in a fully closed oven causing flame to weaken less common

Safe checks you can do yourself

How to reset / clear Oven lights then goes out

  1. Turn the oven OFF and wait a few minutes.
  2. Relight per the manual, holding the knob in long enough for the flame to stabilize.
  3. Release slowly; if it drops out, repeat after reseating/cleaning the thermocouple.
  4. If it still drops out after a clean reseat, plan to replace the thermocouple.

When to call a technician

Call an RV/LP technician if the flame will not hold after reseating and cleaning the thermocouple, if the thermocouple needs replacement and you are not comfortable doing it, or if you ever suspect the safety valve is not shutting off gas when the flame is out.

Applies to

FSRE17 · FSRE21 · FG21MA1EA · FS22N20A · Furrion 2-in-1 range oven · Furrion built-in gas oven

FAQ

What does Furrion Stove / Range code "Oven lights then goes out" mean?

The oven ignites but the flame extinguishes once the knob is released or shortly after. This is the classic flame-supervision-device (thermocouple) fault: the thermocouple must be heated by the pilot/burner flame to generate the small voltage that holds the gas safety valve open. If it does not get hot enough, the safety valve closes and shuts off gas, which is the device working as intended on a marginal flame.

How do I reset Furrion Stove / Range Oven lights then goes out?

Turn the oven OFF and wait a few minutes. Relight per the manual, holding the knob in long enough for the flame to stabilize. Release slowly; if it drops out, repeat after reseating/cleaning the thermocouple. If it still drops out after a clean reseat, plan to replace the thermocouple.

What is the most common cause of Oven lights then goes out on a Furrion Stove / Range?

The most likely cause is thermocouple tip not fully in the flame, bent, or misaligned so it never gets hot enough.

Related · Furrion stove / range

Note: No display codes; symptom-based. Furrion model documentation describes flame supervision generically without a coded fault. Replacement thermocouple availability varies by model.

Last verified 2026-06-29 · compiled from manufacturer documentation. Codes can vary by model year — always cross-check your unit’s manual.