Gas & spark, no flame proven

Atwood Water Heater: “Gas & spark, no flame proven”

warning RV water heater fault codes

Safety A burner that lights but locks out on flame sensing can deposit soot and indicate poor combustion; do not keep it running if you see heavy yellow flame, sooting, or smell exhaust. Never enlarge the orifice and never defeat the ground or safety switches.

What it means

A diagnostic sub-condition of the DSI lock-out: both gas and spark are present but the flame either does not establish or is not sensed reliably, so the board still locks out. Usually a combustion-quality or grounding/alignment problem.

Most likely causes

  1. Incorrect gas pressure (set inlet to 11 inch W.C. with two or more appliances running) most likely
  2. Poor electrical ground (the spark/sense circuit needs a good ground to prove flame) common
  3. Electrodes sparking out of the flame pattern, or to the burner screw, or dirty electrodes common
  4. Partial obstruction or partially blocked orifice in the main burner, or mis-set air shutter common
  5. Mis-aligned flame spreader or solenoid valve/manifold not aligned with the main burner less common
  6. Low DC voltage, partially opening solenoid valve, or defective circuit board less common

Safe checks you can do yourself

How to reset / clear Gas & spark, no flame proven

  1. Switch OFF about 30 seconds and back ON after correcting pressure, ground, or alignment.

When to call a technician

If pressure, ground, electrodes, air, and alignment are correct but the burner still will not stay proven, have a technician check the solenoid valve and board.

Applies to

G6A-8E · GC6AA-10E · GCH6A-10E · GC10A-4E · GCH10A-4E

FAQ

What does Atwood Water Heater code "Gas & spark, no flame proven" mean?

A diagnostic sub-condition of the DSI lock-out: both gas and spark are present but the flame either does not establish or is not sensed reliably, so the board still locks out. Usually a combustion-quality or grounding/alignment problem.

How do I reset Atwood Water Heater Gas & spark, no flame proven?

Switch OFF about 30 seconds and back ON after correcting pressure, ground, or alignment.

What is the most common cause of Gas & spark, no flame proven on a Atwood Water Heater?

The most likely cause is incorrect gas pressure (set inlet to 11 inch w.c. with two or more appliances running).

Related · Atwood water heater

Note: Sub-condition within the single lock-out lamp indication, not a separately displayed code.

Last verified 2026-06-29 · compiled from manufacturer documentation. Codes can vary by model year — always cross-check your unit’s manual.