Spark present, no gas

Atwood Water Heater: “Spark present, no gas”

warning RV water heater fault codes

Safety Sparking with intermittent gas flow can ignite an accumulation of raw propane. Smell for gas, ventilate, and never enlarge the orifice or jumper the ECO. Confirm the LP system has correct pressure before repeated attempts.

What it means

A diagnostic sub-condition of the DSI lock-out from the official trouble-shooting guide: the electrodes are sparking (you hear/see the spark) but no gas reaches the burner, so no flame is proven and the board locks out after three tries.

Most likely causes

  1. Incorrect gas pressure or no gas to the solenoid valve (set inlet to 11 inch W.C. with two or more appliances running) most likely
  2. Blocked main burner tube or blocked/dirty main burner orifice common
  3. Low DC voltage (below ~10.5 VDC) so the solenoid valve will not fully open common
  4. Loose or corroded wiring at the ECO, the solenoid valve, or the circuit board pin connector common
  5. Defective ECO, defective solenoid valve, or defective circuit board less common

Safe checks you can do yourself

How to reset / clear Spark present, no gas

  1. Switch OFF about 30 seconds and back ON after correcting gas pressure, voltage, or a blockage.
  2. Do not repeatedly retry without fixing the cause, since each failed try releases unburned gas into the chamber.

When to call a technician

If gas pressure, voltage, orifice, and wiring are all good but gas still will not feed during spark, have a technician test the solenoid valve and board.

Applies to

G6A-8E · GC6AA-10E · GCH6A-10E · GC10A-4E · GCH10A-4E

FAQ

What does Atwood Water Heater code "Spark present, no gas" mean?

A diagnostic sub-condition of the DSI lock-out from the official trouble-shooting guide: the electrodes are sparking (you hear/see the spark) but no gas reaches the burner, so no flame is proven and the board locks out after three tries.

How do I reset Atwood Water Heater Spark present, no gas?

Switch OFF about 30 seconds and back ON after correcting gas pressure, voltage, or a blockage. Do not repeatedly retry without fixing the cause, since each failed try releases unburned gas into the chamber.

What is the most common cause of Spark present, no gas on a Atwood Water Heater?

The most likely cause is incorrect gas pressure or no gas to the solenoid valve (set inlet to 11 inch w.c. with two or more appliances running).

Related · Atwood water heater