Atwood GC / GCH series fault codes
The 6 fault codes below are the ones that apply to this Atwood water heater family. The other 1 Atwood water heater codes in our database belong to different model families — they are listed further down so you do not troubleshoot against the wrong table.
Covered model numbers
GC6AA-10EGC10A-4EGCH6A-10EGCH10A-4E
Not on the list? Check the rating label before you troubleshoot — the code table below will not apply. Where to find it →
Fault codes on the Atwood GC / GCH series
On Atwood DSI (Direct Spark Ignition) water heaters there is no multi-digit numeric code. … ECO open / tripped warning
The ECO is a backup high-limit temperature switch wired in series with the control. On DSI… Gas & spark, no flame proven warning
A diagnostic sub-condition of the DSI lock-out: both gas and spark are present but the fla… Gas present, no spark warning
A diagnostic sub-condition of the DSI lock-out from the official trouble-shooting guide: g… Spark present, no gas warning
A diagnostic sub-condition of the DSI lock-out from the official trouble-shooting guide: t… TCO (thermal cut-off) tripped danger
Current Atwood DSI water heaters have a one-shot thermal cut-off device on the incoming po…
Codes that do not apply to this model
These 1 codes exist on other Atwood water heaters. If your unit is showing one of them, it is not from this family — re-check the model number on the label before acting on any of these.
Where the model number is
On the data plate behind the outside access door, next to the burner tube — bring a torch, it is often sooted over.
Sources
- Atwood Water Heaters Service Manual (Electronic Ignition Models, DSI Sequence of Operation & Trouble Shooting Guide) — Atwood Mobile Products LLC (DSI Sequence of Operation (Circuit Board: 6-8 sec trial, 3 tries, lock-out + non-ignition lamp); Electronic Ignition Trouble Shooting Guide, effective 2/10/14)
- Atwood Water Heater Service Manual — Heartland Owners (hosted Atwood manual) (Electronic Ignition / DSI section)
- Atwood Water Heaters Service Manual (DSI Sequence of Operation; 110VAC Bolt-In / Screw-In Heating Element, Thermostat & ECO Trouble-Shooting) — Atwood Mobile Products LLC (Pilot Sequence E.C.O. trips above 190F; Screw-In Element ECO backup trips above 170F; manual-reset high-temp limit switch on 110V side)
- Atwood Electronic Ignition Water Heater Trouble Shooting Guide — Atwood Mobile Products LLC (Trouble Shooting Guide, section 'WATER HEATER LOCK OUT - SPARK PRESENT BUT NO GAS', effective 2/10/14)
- Atwood Water Heaters Service Manual (Thermal Cut-Off Device; DSI Sequence of Operation) — Atwood Mobile Products LLC (THERMAL CUT-OFF DEVICE section (one-shot, trips ~190F from blocked burner/flue, breaks circuit, sacrificial); DSI Sequence of Operation 'Thermal Cut-Off')
All Atwood water heater fault codes →
Compare water heater codes across all brands →
Find another model number →