Safety This fridge runs on 12 V DC and is rated at 15 A, fed through a 15 A fuse on 10 AWG wire. Pull the refrigerator fuse before working on wiring or connectors. Note that in this unit the negative and the chassis ground are deliberately not tied together — do not "fix" that by bonding them. The sealed system is charged with R600a (isobutane), which is flammable: never puncture the refrigerant circuit, and keep sparks and open flame away from the compressor compartment.

What it means

Overvoltage. The supply has gone above the range the electronics accept and the unit has protected itself. On a 12 V RV system this is almost always something charging rather than something failing: a converter or DC-DC charger in a high-output stage, an alternator, or a boost/equalise charge applied with the fridge still connected.

Most likely causes

  1. Converter, DC-DC charger or solar controller in a boost/equalise stage lifting the rail above the accepted range most likely
  2. A quick/boost charger connected to the battery with the fridge still wired in common
  3. Alternator or external charger with a wrong or failed regulation setting less common
  4. Wrong battery chemistry profile selected on the charger (for example a lithium profile on a lead-acid bank) less common

Safe checks you can do yourself

How to reset / clear Indicator light 5 flashing

  1. Remove or correct the over-voltage source before anything else.
  2. Pull the refrigerator fuse from the power center, leave it out for 10 minutes, then reinstall it and check the panel.
  3. If the indication returns as soon as charging starts again, the charging source is still out of range — the fridge is reporting correctly.

When to call a technician

The measured supply stays inside a normal charging range at the fridge but the overvoltage indication keeps returning, or a charging source cannot be brought back into range.

Accuracy notes

Lippert's own service manual describes the panel two different ways, and they do not line up. The "Fault Display" table on page 8 assigns meanings to single lights — light 1 refrigerator sensor, 2 ambient sensor, 3 defrost sensor, 4 undervoltage, 5 overvoltage, and lights 1 and 3 together for a fan failure. The service section on pages 19-22 instead reads pairs: lights 1 and 2 for the refrigerator temp sensor in the wind channel, 2 and 3 for the defrost sensor, 3 and 4 for the freezer fan, and all lights for an under/over voltage event. Both readings are reproduced on this site because both are in the manufacturer's document; which one your panel follows appears to depend on the board and firmware revision. Count carefully how many lights are flashing before ordering a part — the pair readings come with concrete component checks, so they are the more useful place to start when two lights are flashing.

Applies to

SRD-360W TG-E · SRD-360WTG-E (LHH-2022302076) · SRD-360WTG-E (RHH-2022302077) · Everchill 10.7 cu. ft. 12V, black glass doors

FAQ

What does Everchill Refrigerator code "Indicator light 5 flashing" mean?

Overvoltage. The supply has gone above the range the electronics accept and the unit has protected itself. On a 12 V RV system this is almost always something charging rather than something failing: a converter or DC-DC charger in a high-output stage, an alternator, or a boost/equalise charge applied with the fridge still connected.

How do I reset Everchill Refrigerator Indicator light 5 flashing?

Remove or correct the over-voltage source before anything else. Pull the refrigerator fuse from the power center, leave it out for 10 minutes, then reinstall it and check the panel. If the indication returns as soon as charging starts again, the charging source is still out of range — the fridge is reporting correctly.

What is the most common cause of Indicator light 5 flashing on a Everchill Refrigerator?

The most likely cause is converter, dc-dc charger or solar controller in a boost/equalise stage lifting the rail above the accepted range.

Related · Everchill refrigerator

Checked against 1 manufacturer document · Last verified 2026-07-27 · compiled from manufacturer documentation. Codes can vary by model year — always cross-check your unit’s manual. How we verify