warning RV refrigerator error codes
What it means
Fan failure. The board is not seeing the evaporator/condenser fan run as expected. A 12 V compressor fridge depends on that airflow: without it the freezer may still make cold, but the cold never reaches the fresh-food compartment, and the compressor runs longer and hotter than it should.
Most likely causes
- Fan connector unplugged or not seated, so the board sees no fan at all most likely
- Fan blade blocked by ice, packaging or debris so the motor stalls common
- Failed fan motor common
- Broken or chafed fan wiring between the board and the fan assembly less common
Safe checks you can do yourself
- Check the red and black fan wires for 12 V with the fridge powered. The service manual gives exactly this test for the paired reading of lights 3 and 4, and it is the quickest way to split a dead fan from a dead feed: voltage present but no rotation means the fan; no voltage means the board or the harness.
- Pull the refrigerator fuse and turn the fan by hand — it should spin freely. Ice around the freezer fan is a common cause and is easy to miss because it melts before the fridge is opened for inspection.
- Check the fan assembly connector at the board (the fan and door switch share the CN1 area of the main board) and look for a lead trapped behind the panel.
- Listen at the start of a cooling cycle. A fan that spins up and then stops, or one that whines and stalls, is failing mechanically even if it turns by hand.
How to reset / clear Indicator lights 1 and 3 flashing
- Clear any ice or obstruction and reconnect the fan before resetting anything.
- Pull the refrigerator fuse for a few minutes, reinstall it and confirm the fan starts with the cooling cycle.
- If the freezer had iced up, defrost it fully before judging whether the fault is gone.
When to call a technician
12 V is present at the fan wires but the fan does not run, or the fault returns after a new fan assembly — the board or the fan circuit needs testing.
Accuracy notes
Lippert's own service manual describes the panel two different ways, and they do not line up. The "Fault Display" table on page 8 assigns meanings to single lights — light 1 refrigerator sensor, 2 ambient sensor, 3 defrost sensor, 4 undervoltage, 5 overvoltage, and lights 1 and 3 together for a fan failure. The service section on pages 19-22 instead reads pairs: lights 1 and 2 for the refrigerator temp sensor in the wind channel, 2 and 3 for the defrost sensor, 3 and 4 for the freezer fan, and all lights for an under/over voltage event. Both readings are reproduced on this site because both are in the manufacturer's document; which one your panel follows appears to depend on the board and firmware revision. Count carefully how many lights are flashing before ordering a part — the pair readings come with concrete component checks, so they are the more useful place to start when two lights are flashing.
Applies to
SRD-360W TG-E · SRD-360WTG-E (LHH-2022302076) · SRD-360WTG-E (RHH-2022302077) · Everchill 10.7 cu. ft. 12V, black glass doors
FAQ
What does Everchill Refrigerator code "Indicator lights 1 and 3 flashing" mean?
Fan failure. The board is not seeing the evaporator/condenser fan run as expected. A 12 V compressor fridge depends on that airflow: without it the freezer may still make cold, but the cold never reaches the fresh-food compartment, and the compressor runs longer and hotter than it should.
How do I reset Everchill Refrigerator Indicator lights 1 and 3 flashing?
Clear any ice or obstruction and reconnect the fan before resetting anything. Pull the refrigerator fuse for a few minutes, reinstall it and confirm the fan starts with the cooling cycle. If the freezer had iced up, defrost it fully before judging whether the fault is gone.
What is the most common cause of Indicator lights 1 and 3 flashing on a Everchill Refrigerator?
The most likely cause is fan connector unplugged or not seated, so the board sees no fan at all.
Related · Everchill refrigerator
Refrigerator sensor fault. The control board is not getting a usable… Indicator light 2 flashing
Ambient temperature sensor fault. The board has lost a plausible reading… Indicator light 3 flashing
Freezer defrost sensor fault. The board cannot read the defrost… Indicator light 4 flashing
Undervoltage alarm. The supply has dropped below what the unit will run… Indicator light 5 flashing
Overvoltage. The supply has gone above the range the electronics accept…
Sources
- Everchill 10.7 cu. ft. 12V Refrigerator (Black Glass Doors) — Troubleshooting and Service Manual — CCD-0008004 Rev 03.25.25 — "Fault Display" table (p. 8), Troubleshooting table (p. 7), "Flashing lights on the temp control panel" (pp. 19-22), Specifications (p. 8) (Lippert Components)
● Checked against 1 manufacturer document · Last verified 2026-07-27 · compiled from manufacturer documentation. Codes can vary by model year — always cross-check your unit’s manual. How we verify